欧姆龙选型 1ER5018 ER 50 18 For the Latest Information On the Internet: www.omron-industrial.com or www.sti.com Compact Rope Pull Emergency Stop Switch ER5018 • Compact size allows this switch to be used on smaller machines with a mounting width of 40 mm and covering ...
欧姆龙选型
1ER5018 ER 50 18 For the Latest Information On the Internet: www.omron-industrial.com or www.sti.com Compact Rope Pull Emergency Stop Switch ER5018 • Compact size allows this switch to be used on smaller machines with a mounting width of 40 mm and covering rope spans up to 40 m • Tension indicator—the tension indicator makes the system easy to set up and to maintain the proper rope tension • Contact arrangements of 2 N/C + 1 N/O or 3 N/C • IP67 (NEMA 6) enclosure enables the ER5018 switch to withstand water washdown cleaning • Heavy-duty housing—the die-cast housing and stainless steel eye nut makes the ER5018 suitable for demanding industrial applications • Integral E-Stop—the optional E-stop provides emer- gency stopping at the extreme end of the installation • Reset button—the blue reset button must be pushed in order to return to “machine run” condition following switch actuation by a pulled or slacked rope • Long life—the ER5018 switch is designed for a min- imum of one million actuations • Vibration tolerant—the snap-acting switch contacts protect against nuisance tripping due to vibration Operation Blue Reset Button A blue reset button is provided to easily return the unit back to its machine-run position after actuation. Emergency Push Button The emergency push button may be installed or repositioned in the field. The ER5018 has two possi- ble mounting positions for the emergency stop button. Installation Hardware Available RK Rope Tension Kit The RK Rope Tension Kit comes with all of the required hardware for most installations. A spring is required as shown in the installa- tion example below. Installation Hardware Individual hard- ware items may be purchased for specific installa- tion requirements. Tension/Gripper Spring Turnbuckle Eyebolt Thimble Double Loop Clip Rope Pulley E53E-EN-01+ER5018+Datasheet.fm Seite 1 Freitag, 12. Oktober 2007 12:35 12 2 Compact Rope Pull Emergency Stop Switch For the Latest Information On the Internet: www.omron-industrial.com or www.sti.com Contact Arrangements Mounting Specification Note: Some installations may require a ER5018 on each end. Applications Typical applications are on conveyor systems and across rotating machinery, and around hazardous areas. Ordering information Compact Rope Pull Emergency Stop Switch Accessories E-Stop Contacts Wiring Entry Model Not included 2 N/C + 1 N/O 3 x M20 ER5018-021M Not included 3 N/C 3 x M20 ER5018-030M Included 2 N/C + 1 N/O 3 x M20 ER5018-021ME Included 3 N/C 3 x M20 ER5018-030ME Item Model Replacement Lid SM06-SL400 Rope Kit, 5 m, Stainless Steel RK5 Rope Kit, 10 m, Stainless Steel RK10 Rope Kit, 20 m, Stainless Steel RK20 Rope Kit, 50 m, Stainless Steel RK50 Rope Only, 5 m R5M Rope Only, 10 m R10M Rope Only, 20 m R20M Rope Only, 50 m R50M Rope Only, 100 m R100M Rope Only, 126 m R126M Tensioner Gripper, Stainless Steel SM06-TG00 Eye Bolt Stainless Steel, 8 per pack SM06-EB10 Double Loop Clip, Stainless Steel, 4 per pack SM06-DL20 Thimble Stainless Steel, 4 per pack SM06-THSS 0 mm 11/12 21/22 33/34 2NC + 1NO Versions Rope Slack Tension Range Rope Pulled Contact Open Contact Closed 11/12 21/22 31/32 3NC Versions Rope Slack Tension Range Rope Pulled 14.5 mm 17.0 mm3.5 mm ER5018 ≤ 40 m ≤ 500 mm ≤ 500 mmEvery ≤ 3 m Every ≤ 3 m Eyebolt Support Safety Spring WallTensioner Gripper E53E-EN-01+ER5018+Datasheet.fm Seite 2 Freitag, 12. Oktober 2007 12:35 12 3ER5018 ER 50 18 For the Latest Information On the Internet: www.omron-industrial.com or www.sti.com Specifications Note: The safety contacts of the Omron STI switches are described as normally closed (N/C)—i.e., with the rope properly tensioned and the machine able to be started. Dimensions Turnbuckle, Stainless Steel SM06-TB30 Spring, Stainless Steel SM06-SP50 Rope Pulley, Stainless Steel SM06-RPSS E-Stop Mechanism SM06-ES60 Electrical Contact Configurations 2 N/C + 1 N/O, 3 N/C Safety Contacts 2 N/C, 3 N/C Switching Ability AC: 120 V–6 A, 240 V–3 A, InductiveDC: 24 V–2.5 A, Inductive Auxiliary Contacts 1 N/O Max Switching Current/Volt/Amp 240 V/720 VA Minimum Current 5 V, 5 mA DC Electrical Life 1,000,000 minimum Mechanical Mounting Any position Mounting Hardware 2 x M5 screws Actuator Travel for Positive Opening See diagrams on previous page Max Rope Span 40 m Operation Force < 125 N Tensioning Force to Run Position 130 N typical Case Material Die-cast aluminum alloy Eye Nut Material Stainless steel Wiring Entry 3 x M20 Weight 675 g Color Yellow Mechanical Life 1,000,000 minimum Environmental Protection IP67 (NEMA 6) Operating Temperature -25 to 80°C Cleaning Water washdown Compliance Standards IEC947-5-1, IEC947-5-5, EN418, UL508, BS5304 Approvals/Listings CE marked for all applicable directives, UL and C-UL Item Model 74 57 23 90139 40 46 25 25 10 57 188 205MIN - MAX 2 mtg holes clearance for M5 screws E53E-EN-01+ER5018+Datasheet.fm Seite 3 Freitag, 12. Oktober 2007 12:35 12 4 Compact Rope Pull Emergency Stop Switch For the Latest Information On the Internet: www.omron-industrial.com or www.sti.com Safety precautions Operating instructions Installation must be in accordance with the following steps and stated specifications and should be carried out by suitably competent personnel. Adherence to the recommended maintenance instructions forms part of the warranty. ! WARNING Do not defeat, tamper, remove or bypass this unit. Severe injury to personnel could result. W ! WARNING 1. Installation of all Safety Rope Switch systems must be in accordance with a risk assessment for the individual application. Installation must only be carried out by competent personnel and in accordance with these instructions. 2.Rope support eyebolts must be fitted at 2.5 m. min. to 3 m. max. inter- vals along all rope lengths between switches. The rope must be supported no more than 500 mm from the switch eyebolt or Safety Spring (if used). It is important that this first 500 mm is not used as part of the active protection coverage. 3.M5 mounting bolts must be used to fix the switches. Tightening torque for mounting bolts to ensure reliable fixing is 4 Nm. Tightening torque for the lid screws, conduit entry plugs and cable glands must be 1.5 Nm to ensure IP seal. Only use correct sizing glands for conduit entry and cable outside diameter. 4.Tensioning of rope is achieved by use of tensioner / gripper assemblies. Upon installation, tension to mid-position as indicated by the red arrows in the viewing window of each switch. Check operation for all switches and the control circuits by puling the rope at various locations along the active protection area and resetting each switch by depressing the Blue Reset button. Ensure each time that the switches latch off and require manual resetting by depressing the Blue Reset button. Increase the sys- tem tension further, if required, depending upon the checks along the active length of coverage. If fitted with a Mushroom type E-Stop button (Red) then test and reset each switch to ensure function of control cir- cuits. Typical operational conditions for successful operation of system is less than 75 N. pulling force and less than 150 mm deflection of rope between eyebolt supports. If the optional LED is fitted but is not used, ensure that the conductors remain coiled and tied to the tie hole in the LED flange. 5.Every week: Check correct operation of system at locations along all coverage length. Check for nominal tension setting, re-tension rope if necessary. Every 6 months: Isolate power and remove cover. Check screw terminal tightness and check for signs of moisture ingress. Never attempt to repair any switch. (120VAC) (120VAC) Green Red (common ) Black Red Green Black(+24VDC) (+24VDC) Optional 24 VDC Indicator Beacon When +24VDC is applied to the red wire, the beacon will illuminate red and flash. When +24 VDC is applied to the green wire, the beacon will illuminate green. Optional 120 VAC Indicator Beacon When +120VAC is applied to the red wire, the beacon will illuminate red and flash. When +120 VAC is applied to the green wire, the beacon will illuminate green. (0 V) Tension Indicator Indicator shown with steel rope properly adjusted. In the interest of product improvement, specifications are subject to change without notice. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. E53E-EN-01 E53E-EN-01+ER5018+Datasheet.fm Seite 4 Freitag, 12. Oktober 2007 12:35 12
/
本文档为【欧姆龙选型】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索