600T刚腿吊耳计算600T刚腿吊耳计算
Rigid leg section 6#
按照单侧吊耳受力400T计算.
Double link end
Pl 50
R360
4 x 0 x (0 / 2 - 25.2 / 2 ) =
252
Pl 0 x 0
02sides
Fy33.5kN/cm2
P3920 kN
A end2 x 5 x (0 + 36 - 25.2 / 2 ) =234.0
4 x 0 x (0 / 2 - 25.2 / 2 ) =0.0
234.0
f end3920 / 234 =16.821.8okA net2 ...
600T刚腿吊耳计算
Rigid leg section 6#
按照单侧吊耳受力400T计算.
Double link end
Pl 50
R360
4 x 0 x (0 / 2 - 25.2 / 2 ) =
252
Pl 0 x 0
02sides
Fy33.5kN/cm2
P3920 kN
A end2 x 5 x (0 + 36 - 25.2 / 2 ) =234.0
4 x 0 x (0 / 2 - 25.2 / 2 ) =0.0
234.0
f end3920 / 234 =16.821.8okA net2 x 5 x ( 2 x 36 - 25.2 ) =468.0
4 x 0 x (0 - 25.2 ) =0.0
468.0
f net3920 / 468 =8.415.1okAbrg25.2 x 2 x ( 5 + 2 x 0 ) =252.0fbrg3920 / 252 =15.620.1ok
Single end connection
Pl 40
R340
2 x 3 x (65 / 2 - 25.2 / 2 ) =
252
Pl 30 x 650
0
Fy33.5kN/cm2
P3920 kN
A end4 x (0 + 36 - 25.2 / 2 ) =93.6
2 x 3 x (65 / 2 - 25.2 / 2 ) =119.4
213.0
f end3920 / 213 =18.421.8okA net4 x ( 2 x 36 - 25.2 ) =187.2
2 x 3 x (65 - 25.2 ) =238.8
426.0
f net3920 / 426 =9.215.1okAbrg25.2 x ( 4 + 2 x 3 ) =252.0fbrg3920 / 252 =15.620.1ok
有限元计算
按照单个吊耳受力400T计算.
2最大应力为23.276kN/cm=232.76Mpa
[,],335/1.1,304.5Mpa根据FEM规范,吊装属于三类非工作工况安全系数取1.1. a符合规范要求.