为了正常的体验网站,请在浏览器设置里面开启Javascript功能!

ION7650智能电表

2013-07-12 12页 pdf 983KB 20阅读

用户头像

is_800450

暂无简介

举报
ION7650智能电表 Technical data sheet 2007 PowerLogic power-monitoring units 0 ION7550/ION7650 2 ION7550 M7550 ION7650 M7650 See page 6 for order code explanations. Power-monitoring units ION7550 / ION7650 0 Functions and characteristics P E 86 01 7 PowerLogic I...
ION7650智能电表
Technical data sheet 2007 PowerLogic power-monitoring units 0 ION7550/ION7650 2 ION7550 M7550 ION7650 M7650 See page 6 for order code explanations. Power-monitoring units ION7550 / ION7650 0 Functions and characteristics P E 86 01 7 PowerLogic ION 7650. Used at key distribution points and sensitive loads, ION7550 and ION7650 meters offer unmatched functionality including advanced power quality analysis coupled with revenue accuracy, multiple communications options, web compatibility, and control capabilities. Integrate these meters with our PowerLogic® ION Enterprise software or share operations data with existing SCADA systems through multiple communication channels and protocols. Applications Reduce energy costs. Increase equipment utilisation. Comply with environmental and regulatory requirements. Improve power quality and reliability. Improve customer satisfaction and retention. Monitor and control equipment. Integrated utility metering. Instrument transformer correction. Main characteristics Increase efficiency Reveal energy inefficiencies or waste and optimise equipment operation to increase efficiency. Allocate costs Allocate or sub-bill energy costs to departments, processes or tenants. Summarise power quality Consolidate all the power quality characteristics into a single trendable index. Anticipate, diagnose and verify Isolate reliability risks, diagnose power-related equipment issues and verify reliable operation. Set targets, measure and verify results Benchmark power quality and reliability and compare against standards, or compare facilities or processes. Easy to operate Screen-based menu system to configure meter settings. Bright LCD display with adjustable contrast. Integrate with software Easily integrated with PowerLogic or other energy management systems, including Itron MV-90. Detect and capture short transients as short as 20µs at 50Hz (17µs at 60 Hz) Identify problems due to short disturbances, e.g. switching of capacitors, etc. Evaluate flicker based on IEC 61000-4-15 and IEEE 1453 Measure rapid variations in voltage. Verify electrical quality compliance with EN 50160 Fast standardised check on the quality of the electricity supplied. Detect major waveform changes Detection of phase switching phenomena (for example during the transfer of a high- speed static switch) not detected by classical threshold-based alarms. Record ultra-fast electrical parameters every 100 ms or every cycle Preventive maintenance: acquisition of a motor startup curve, etc. Trend curves and short-term forecasting Rapid trending and forecasting of upcoming values for better decision making. Set automatic alarms Alarm setpoint learning feature for optimum threshold settings. Up to 10 Mbytes of memory For archiving of data and waveforms. Notify alarms via email High-priority alarms sent directly to the user's PC. Instant notification of power quality events by email. Part numbers ION7550 / ION7650 3 DNP 3.0 through serial, modem, and I/R ports b b (1) For 50 Hz line frequency; 17µs for 60 Hz line frequency. (2) Standard current range only. 50 A for optional current range. Power-monitoring units ION7550 / ION7650 0 Functions and characteristics (cont.) P E 86 01 8 PowerLogic® ION7550 / ION7650. 1 Current/voltage inputs. 2 I/O expansion card. 3 Digital inputs. 4 Analog inputs. 5 Analog outputs. 6 Communications card. 7 Power supply. 8 Form C digital outputs. 9 Digital inputs. 10 Form A digital outputs. Selection guide ION7550 ION7650 General Use on LV and HV systems b b Current accuracy (1A to 5A) 0.1 % reading 0.1 % reading Voltage accuracy (57V to 288V) 0.1 % reading 0.1 % reading Energy accuracy 0.2 % 0.2 % Nbr of samples/cycle or sample frequency 256 1024 Instantaneous rms values Current, voltage, frequency b b Active, reactive, apparent power Total and per phase b b Power factor Total and per phase b b Current measurement range extended to 500 A for 1 second(2) b b Energy values Active, reactive, apparent energy b b Settable accumulation modes b b Demand values Current Present and max. values b b Active, reactive, apparent power Present and max. values b b Predicted active, reactive, apparent power b b Synchronisation of the measurement window b b Setting of calculation mode Block, sliding b b Power quality measurements Harmonic distortion Current and voltage b b Individual harmonics Via front panel 63 63 Via ION Enterprise 127 511 Waveform capture b b Detection of voltage swells and sags b b Adaptive waveform capture (up to 64 s) b b Detection and capture of transients 20 µs1 20 µs1 Flicker - b Fast acquisition of 100 ms or 20 ms data b b EN50160 compliance checking b b Programmable (logic and math functions) b b Data recording Min/max of instantaneous values b b Data logs b b Event logs b b Trending/forecasting b b SER (Sequence of event recording) b b Time stamping b b GPS synchronisation (1 ms) b b Memory (in Mbytes) 10 10 Display and I/O P E 86 00 2 Front panel display b b Wiring self-test b b Pulse output 1 1 Digital or analogue inputs(max) 24 24 Digital or analogue outputs (max, including pulse output) 30 30 Communication RS 485 port 1 1 RS 485 / RS 232 port 1 1 Optical port 1 1 Modbus protocol b b Ethernet port (Modbus/TCP/IP protocol) 1 1 Disturbance waveform capture and power quality report Ethernet gateway (EtherGate) 1 1 Alarms (optional automatic alarm setting b b Alarm notification via email (Meterm@il) b b HTML web page server (WebMeter) b b Internal modem 1 1 Modem gateway (ModemGate) b b 4 Power-monitoring units ION7550 / ION7650 0 Functions and characteristics (cont.) PowerLogic ION7550 Electrical characteristics P E 86 01 7 Type of measurement True rms up to 1024 samples per cycle Measurement accuracy Current and voltage ±0.01% of reading + ±0.025% of full scale Power ±0.075% of reading + ±0.025% of full scale Frequency ±0.005Hz Power factor ±0.002 from 0.5 leading to 0.5 lagging Energy: IEC62053-22 0,2S, 1A and 5A Data update rate 1/2 cycle or 1 second Input-voltage characteristics Measured voltage Autoranging 57V through 347V LN / 600V LL Measurement range 85 to 240VAC and 110 to 330VDC Impedance 5 MΩ/phase (phase - Vref) Frequency measurement range 47 to 63Hz Input-current characteristics Rated nominal current 1A, 2A, 5A, 10A Measurement range 0.005 - 20 A autoranging (standard range) 0.001 - 10 A autoranging (optional range) Permissible overload 500 A rms for 1 s, non-recurring (at 5A) 50 A rms for 1s, non-recurring (at 1A) Impedance 0.002 Ω per phase (5A) 0.015 Ω per phase (1A) Burden 0.05 VA per phase (at 5 A) 0.015 VA per phase (at 1 A) Power supply AC 85-240 V AC ±10% (47-63 Hz) DC 110-300 V DC ±10% DC low voltage (optional) 20-60 V DC ±10% Ride-through time 100 ms (6 cycles at 60 Hz) min. at 120 V DC Burden Standard: typical 15 VA, max 35 VA Low voltage DC: typical 12 VA, max 18 VA Input/outputs(1) Standard 8 digital inputs (120 V DC) 3 relay outputs (250 V AC / 30 V DC) 4 digital outputs (solid state) Optional 8 additional digital inputs 4 analog outputs, and/or 4 analog inputs Mechanical characteristics Weight 1.9 kg IP degree of protection (IEC 60529) IP52 Dimensions Standard model 192 x 192 x 159 mm TRAN model 235.5 x 216.3 x 133.1 mm Environmental conditions Operating temperature Standard power supply -20 to +70ºC Low voltage DC supply -20 to +50ºC Display operating range -20 to +70ºC Storage temperature Display, TRAN -40 to +85ºC Humidity rating 5 to 95% non-condensing Installation category III (2000m above sea level) Dielectric withstand As per EN 61010-1, IEC 62051-22A(2) Electromagnetic compatibility Electrostatic discharge IEC 61000-4-2 Immunity to radiated fields IEC 61000-4-3 Immunity to fast transients IEC 61000-4-4 Immunity to surges IEC 61000-4-5 Conducted and radiated emissions CISPR 22 Safety Europe IEC 61010-1 (1) Consult the ION7550 / ION7650 installation guide for complete specifications. (2) IEC 62051-22B with serial ports only. 5 Example showing instantaneous values and alarm. Languages English (1) All the communication ports may be used simultaneously. Power-monitoring units ION7550 / ION7650 0 Functions and characteristics (cont.) P E 86 00 4 Example WebMeter page showing realtime values. Communication RS 232/485 port (1) Up to 115,200 bauds (57,600 bauds for RS 485), ION, DNP 3.0, Modbus, GPS, EtherGate, ModemGate, Modbus Master RS 485 port (1) Up to 57,600 bauds, ION, DNP 3.0, Modbus, GPS, EtherGate, ModemGate, Modbus Master Infrared port(1) ANSI type 2, up to 19,200 bauds, ION, Modbus, DNP 3.0 Ethernet port 10 BaseT, RJ45 connector, 100 m link Fibre-optic Ethernet link 10 Base FL, LC duplex connector, 1300 nm, FO multimode with gradient index 62.5/125 µm or 50/125 µm, 2000 m link Protocol ION, Modbus, TCP/IP, DNP 3.0, Telnet EtherGate Communicates directly with up to 62 slave devices via available serial ports ModemGate Communicates directly with up to 31 slave devices WebMeter 5 customisable pages, new page creation capabilities, HTML/XML compatible Firmware characteristics High-speed data recording Down to 5ms interval burst recording, stores detailed characteristics of disturbances or outages. Trigger recording by a user-defined setpoint, or from external equipment. Harmonic distortion Up to 63rd harmonic (511th for ION7650 via ION Enterprise software) for all voltage and current inputs Sag/swell detection Analyse severity/potential impact of sags and swells: - magnitude and duration data suitable for plotting on voltage tolerance curves - per phase triggers for waveform recording or control operations Instantaneous High accuracy (1s) or high-speed (1/2 cycle) measurements, including true rms per phase / total for: - voltage and current - active power (kW) and reactive power (kvar) - apparent power (kVA) - power factor and frequency - voltage and current unbalance - phase reversal Load profiling Channel assignments (800 channels via 50 data recorders) are configurable for any measurable parameter, including historical trend recording of energy, demand, voltage, current, power quality, or any measured parameter. Trigger recorders based on time interval, calendar schedule, alarm/event condition, or manually. Trend curves Access historical data at the front panel. Display, trend and continuously update historical data with date and timestamps for up to four parameters simultaneously. Waveform captures Simultaneous capture of all voltage and current channels - sub-cycle disturbance capture - maximum cycles is 214,000 (16 samples/cycle x 96 cycles, 10Mbytes memory) - 256 samples/cycle (ION7550) - 512 samples/cycle standard, 1024 samples/cycle optional (ION7650) P E 86 00 5 Alarms Threshold alarms: - adjustable pickup and dropout setpoints and time delays, numerous activation levels possible for a given type of alarm - user-defined priority levels - boolean combination of alarms is possible using the operators NAND, OR, NOR and XOR Advanced security Up to 16 users with unique access rights. Perform resets, time syncs, or meter configurations based on user privileges Transformer correction Correct for phase / magnitude inaccuracies in current transformers (CTs), potential transformers (PTs) Memory 5 to 10 Mbytes (specified at time of order) Firmware update Update via the communication ports Display characteristics Integrated display Back lit LCD, configurable screens 6 four 0 to 1 analog inputs and four -1 to 1 mA analog outputs) 9 Security 0 Password protected, no hardware lock 1 Password protected and hardware lockable (lock enabled/disabled via jumper on comm card) 10 Special Order A None C Tropicalisation treatment applied. E EN50160 compliance monitoring, no tropicalisation treatment F EN50160 compliance monitoring, with tropicalisation treatment Power-monitoring units ION7550 / ION7650 0 Functions and characteristics (cont.) Part numbers Example ION7650 product part number. Item Code Description P E 86 02 0 1 Model M7650 Advanced meter with wide-range voltage inputs (57-347V line- neutral or 100-600V line-line), transient detection, data and waveform recording. Supports ION, Modbus-RTU, and DNP 3.0. M7550 Advanced meter with wide-range voltage inputs (57-347V line- neutral or 100-600V line-line), sag/swell detection, data and waveform recording, and 256 samples/cycle resolution. 2 Form Factor A0 Integrated display with front optical port, 5 MB logging memory, and 512 samples/cycle resolution. 1 Model. 2 Form factor. 3 Current Inputs. 4 Voltage Inputs. 5 Power supply. 6 System frequency. 7 Communications. 8 Inputs/outputs. 9 Security. 10 Special order. A1 ION7650 only. Integrated display with front optical port, 5 MB logging memory, and 1024 samples/cycle resolution. B0 Integrated display with front optical port, 10 MB logging memory, and 512 samples/cycle resolution. B1 ION7650 only. Integrated display with front optical port, 10 MB logging memory, and 1024 samples/cycle resolution. T0 Transducer (no display) version, with 5 MB logging memory, and 512 samples/cycle resolution. T1 ION7650 only. Transducer (no display) version, with 5 MB logging memory, and 1024 samples/cycle resolution. U0 Transducer (no display) version, with 10 MB logging memory, and 512 samples/cycle resolution. U1 ION7650 only. Transducer (no display) version, with 10 MB logging memory, and 1024 samples/cycle resolution. 3 Current Inputs C 5 Amp nominal, 20 Amp full scale current input E 1 Amp nominal, 10 Amp full scale current input F Current Probe Inputs (for use with 0-1 VAC current probes; probes sold separately) G Current Probe Inputs with three Universal Technic 10A clamp on CTs; meets IEC 1036 accuracy 4 Voltage Inputs 0 57 to 347 VAC line-to-neutral / 100 to 600 VAC line-to-line 5 Power Supply B Standard power supply (85-240 VAC, ±10%/47-63 Hz / 110-330 VDC, ±10%) C Low voltage DC power supply (20-60 VDC) 6 System Frequency 5 Calibrated for 50 Hz systems 6 Calibrated for 60 Hz systems 7 Communications A0 Standard communications (1 RS-232/RS-485 port, 1 RS-485 port). Integrated display models also include 1 ANSI Type 2 optical communications port. C1 Standard communications plus 10Base-T Ethernet (RJ45), 33.6k universal internal modem (RJ11). Ethernet and modem gateway functions each use a serial communications port. D1 Standard communications plus 10Base-T Ethernet (RJ45) and 10BaseFL Ethernet fibre, 33.6k universal internal modem (RJ11). Ethernet and modem gateway functions each use a serial communications port. E0 Standard communications plus 10Base-T Ethernet (RJ45). Ethernet gateway function uses a serial communications port. F0 Standard communications plus 10Base-T Ethernet (RJ45) and 10Base-FL (ST male fibre optic connection). Ethernet gateway function uses a serial communications port. M1 Standard communications plus 33.6k universal internal modem (RJ11). Modem gateway function uses a serial communications port. 8 I/O A Standard I/O (8 digital inputs, 3 Form C relays, 4 Form A solid-state outputs) D Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 1 mA analog inputs) E Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs) H Standard I/O plus Expansion I/O card (8 additional digital inputs & four -1 to 1 mA analog outputs) K Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog outputs) N Standard I/O plus Expansion I/O card (8 additional digital inputs & four 0 to 20 mA analog inputs and four 0 to 20 mA outputs) P Standard I/O plus Expansion I/O card (8 additional digital inputs & M 7 Power-monitoring units ION7650 / ION7550 0 Functions and characteristics (cont.) Part numbers (cont’d) Communications Card P E 86 02 1 Example order code. Use this group of codes when ordering the ION7550/7650 communications or I/O cards. Item Code Description 1 Comm card P760C ION7550 / ION7650 communication card for field retrofit installations 2 Type A0 Standard communications (1 RS-232/RS-485 port, 1 RS-485 port). Front optical port support for meters with integrated display. C1 Standard communications plus 10Base-T Ethernet (RJ45), 33.6k universal internal modem (RJ11; the modem port is shared with the front optical port). Ethernet and modem gateway functions each use a serial communications port. 1 Communications or I/O card. 2 Type 3 Special order. D1 Standard communications plus 10Base-T Ethernet, 10BaseFL Ethernet fibre, 33.6k universal internal modem (RJ11; the modem port is shared with the front optical port). Ethernet and modem gateway functions each use a serial communications port. E0 Standard communications plus 10Base-T Ethernet. Ethernet gateway function uses a serial communications port. F0 Standard communications plus 10Base-T Ethernet, 10BaseFL Ethernet fibre. Ethernet gateway function uses a serial communications port. M1 Standard communications plus 33.6k universal internal modem (RJ11; the modem port is shared with the front optical port). Modem gateway function uses a serial communications port. 3 Special order A None C Tropicalization treatment applied Input/Output expansion card Item Code Description I/O card P760A Expansion I/O for field retrofit installations. Type D Expansion I/O card with eight digital inputs, four 0 to 1 mA analog inputs E Expansion I/O card with eight digital inputs, four 0 to 20 mA analog inputs H Expansion I/O card with eight digital inputs, four -1 to 1 mA analog outputs K Expansion I/O card with eight digital inputs, four 0 to 20 mA analog outputs N Expansion I/O card with eight digital inputs, four 0 to 20 mA analog inputs & four 0 to 20 mA outputs P Expansion I/O card with eight digital inputs, four 0 to 1 analog inputs and four -1 to 1 mA analog outputs Special Order A None P E 86 01 9 P o w e r L o g i c ION7550 TRAN C Tropicalization treatment applied Transducer unit (TRAN) Item Code Description ION7550 TRAN T0 ION7550 TRAN (no display), 5MB memory U0 ION7550 TRAN (no display), 10MB memory ION7650 TRAN T0 ION7650 TRAN (no display), 5MB memory T1 ION7650 TRAN (no display), 10MB memory, 1024 samples/cycle U0 ION7650 TRAN (no display), 10MB memory U1 ION7650 TRAN (no display), 10MB memory, 1024 samples/cycle Terminal covers Item Code Description Terminal covers TERM CVR- 7500 Two covers: one for the strip containing the relays and digital inputs (lower), and another for the strip containing the phase current and voltage inputs (upper). P C 1 8 Power-monitoring units ION7550 / ION7650 0 Installation and connection ION7550/ION7650 dimensions P E 86 02 2 P E 86 02 3 ION7550 / ION7650 TRAN dimensions P E 86 02 4 P E 86 02 5 P E 86 02 6 Front-panel mounting P E 86 02 7 9 Connection representation only. Other types of connection are possible. See product installation guide for complete wiring and communication connection details. Power-monitoring units ION7550 / ION7650 0 Installation and connection (cont.) 4-wire direct connections P E 86 02 8 Connection representation only. Other types of connection are possible. See product installation guide for complete wiring and communication connection details. 4-wire 3 element connection with 4 CTs and 3 PT P E 86 02 9 Protection (3A) Protection (2A) Shorting block N L1 L2 L3 L/+ N/- Power supply Fuse for N/- required if neutral is ungrounded I4 optional} I11 I12 I21 I22 I32 I42 I31 I41 V1 V2 V3 V4 Connect G terminal to ground for AC power source Vref I51 I52 Protection (3A) Shorting block N L1 L2 L3 L/+ N/- Power supply Fuse for N/- required if neutral is ungrounded I4 optional} I11 I12 I21 I22 I32 I42 I31 I41 V1 V2 V3 V4 Connect G terminal to ground for AC power source Vref I51 I52 Protect
/
本文档为【ION7650智能电表】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索