为了正常的体验网站,请在浏览器设置里面开启Javascript功能!

阿牛巴

2010-09-02 20页 pdf 1MB 47阅读

用户头像

is_043811

暂无简介

举报
阿牛巴 Product Data Sheet 00813-0100-4028, Rev CA March 2008 Rosemount 285 Annubar Primary Element • Des • Incr ma • Ene per • Ind cre (AP Ros Rosemount 285 Annubar® Pri Contents The 285 Annubar Primary Element Series . . . . . . . . . . . . . . . . . . . . ...
阿牛巴
Product Data Sheet 00813-0100-4028, Rev CA March 2008 Rosemount 285 Annubar Primary Element • Des • Incr ma • Ene per • Ind cre (AP Ros Rosemount 285 Annubar® Pri Contents The 285 Annubar Primary Element Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 2 285 Annubar Primary Element Series Selection Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 3 Rosemount 285 Annubar Primary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4 Dimensional Drawings. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 6 Configuration Data Sheet (CDS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 12 Fluid Data Sheet (FDS) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15 www.ro igned for general purpose applications eased plant uptime with the intenance-free design rgy savings gained through minimal manent pressure loss ustry leading integrated DP flowmeters are ated when Annubar Averaging Pitot Tube T) primary elements are packaged with emount pressure transmitters mary Element Series semount.com Product Data Sheet 00813-0100-4028, Rev CA March 2008Rosemount 285 Annubar Primary Element The 285 Annubar Primary Element Series Designed for general purpose applications The Annubar’s revolutionary shape with sensing holes, promises the best accuracy and repeatability in applications with low to medium pressure and temperature requirements. Plant uptime is increased with the maintenance-free design The Annubar sensor is designed to prevent wear and blockage in the pipe. The electronics are the most stable in the industry and allows up to 10 year calibration cycles, providing significant maintenance savings. Energy savings gained through minimal permanent pressure loss The non-constricting design of the Annubar sensor creates minimal blockage in the pipe, which reduces permanent pressure loss. Permanent pressure loss can be converted directly into energy savings in the form of compressor cost for gas, electrical cost for pumping liquids, and fuel costs for generating steam. Industry leading integrated DP flowmeters By integrating pressure transmitter electronics with the Annubar, Rosemount provides the highest performing insertion DP flowmeter. This fully integrated flowmeter eliminates the need for instrument fittings, tubing, valves, adapters, manifolds, and mounting brackets, thereby reducing welding and installation time. Advanced PlantWeb® Functionality Rosemount Annubar flowmeters power PlantWeb through a scalable architecture, advanced diagnostics, and MultiVariable capabilities. This reduces operational and maintenance expenditures while improving throughput and utilities management. Rosemount DP Flow Solutions Annubar Flowmeter Series: Rosemount 3051SFA, 3095MFA, 485, and 285 The state-of-the-art, fifth generation Rosemount 485 Annubar combined with the 3051S or 3095MV MultiVariable transmitter creates an accurate, repeatable and dependable insertion-type flowmeter. The Rosemount 285 provides a commercial product offering for your general purpose applications. Compact Orifice Flowmeter Series: Rosemount 3051SFC, 3095MFC, and 405 Compact Orifice Flowmeters can be installed between existing flanges, up to a Class 600 (PN100) rating. In tight fit applications, Integral Orifice Flowmeter Series: Rosemount 3051SFP, 3095MFP, and 1195 These integral orifice flowmeters eliminate the inaccuracies that become more pronounced in small orifice line installations. The completely assembled, ready to install flowmeters reduce cost and simplify installation. Orifice Plate Primary Element Systems: Rosemount 1495 and 1595 Orifice Plates, 1496 Flange Unions and 1497 Meter Sections A comprehensive offering of orifice plates, flange unions and meter sections that is easy to specify and order. The 1595 Integral mount head allows close coupling to most Rosemount transmitters which provides flowmeter capabilities. 2 a conditioning orifice plate version is available, requiring only two diameters of straight run upstream. Conditioning Orifice provides superior performance in tight fit applications. Product Data Sheet 00813-0100-4028, Rev CA March 2008 Rosemount 285 Annubar Primary Element 285 Annubar Primary Element Series Selection Guide Rosemount 285 Annubar with Pak-Lok Mounting • Designed to give the highest performance in applications with low to medium pressure and temperature requirements • Innovative T-shape design provides accuracy to ±1.00% • Optional integral manifold head allows direct mounting of DP transmitters • Ideal fluid type: liquid, gas, and steam Rosemount 285 Annubar with Duct Mount (No compression fitting) • Combines the 285 Annubar technology with duct mounting installation • For applications requiring duct mounting installation • Ideal fluid types: gas • Threaded stud for opposite side support Rosemount 285 Annubar with Duct Mount Compression Fitting • For application in ducts requiring additional mounting support • Ideal fluid types: gas • No opposite side support required Rosemount 285 Annubar with Pak-Lok Mounting Rosemount 285 Annubar with Duct Mount Rosemount 285 Annubar with Duct Mount Compression Fitting 3 Product Data Sheet 00813-0100-4028, Rev CA March 2008Rosemount 285 Annubar Primary Element Rosemount 285 Annubar Primary SPECIFICATIONS Performance Performance Statement Assumptions Measured pipe I.D. Discharge Coefficient Factor Liquid: ±1.0% of flow rate Gas and Steam: ±2.0% of flow rate Repeatability ±0.1% Line Sizes • Sensor Size 1: 2-in. to 8-in. (50 to 200 mm) • Sensor Size 2: 8-in. and above For larger line sizes, consult factory. NOTE Some mounting styles not available in large line sizes. TABLE 1. Reynolds Number and Probe Width Sizing Contact an Emerson Process Management representative for assistance. A Configuration Data Sheet is required prior to order for application verification. Flow Turndown 10:1or better Functional Service • Liquid • Gas • Steam (limited) Temperature Limits(1) • -40 to 300°F (-40 to 149°C) • -40 to 850°F (-40 to 454°C) for Duct Mount Version (D1) only Pressure Limits(1) • Pak-Lok: 150# ANSI (275 psig at 100 °F (19 bar at 38 °C)) • Duct Mount (D1 & D2): 10 PSIG (0.6 bar) Pressure and Temperature Limits Direct Mount Electronics • Up to 150# ANSI (275 psig at 100 °F (19 bar at 38 °C)) • Maximum temperature: 500 °F (260 °C) • Integral temperature measurement is not available. Remote Mount Electronics • Up to 150# ANSI (275 psig at 100 °F (19 bar at 38 °C)). • Integral temperature measurement is not available. Physical Annubar Sensor Material • 316 Stainless Steel Pak-Lok See “Dimensional Drawings” on page 6 Pak-Lok Model (option P1) • Provided with a compression sealing mechanism rated up to 150# ANSI (275 psig at 100 °F (19 bar at 38 °C)) • PTFE Packing (–40 to 300 °F (–40 to 149 °C)) Duct Mount See “Dimensional Drawings” on page 7. Duct Mount without Compression Fitting Model (option D1) • Provided with duct mounting rated up to 10 psig at 850°F (0.6 bar at 454°C). Duct Mount with Compression Fitting See “Dimensional Drawings” on page 8. Duct Mount with Compression Fitting Model (option D2) • Provided with duct mount compression fitting rated up to 10 psig at 300°F (0.6 bar at 38°C). Instrument Connections Temperature Ranges Sensor Size Minimum Rod Reynolds Number (Rd) Probe Width (d) (inches) 1 6500 0.590-in. (14.99 mm) 2 12500 1.060-in. (26.92 mm) Where d = Probe width (feet) v = Velocity of fluid (ft/sec) p = Density of fluid (lbm/ft3) µ = Viscosity of the fluid (lbm/ft-sec) Rd d v× p× µ ---------------------= TABLE 2. Minimum / Maximum Temperature Range Code Description Temperature G1 Needle Valves, Carbon Steel -40 to 500°F (-40 to 260°C) G2 Needle Valves, Stainless Steel -40 to 500°F (-40 to 260°C) B1 Ball Valve, Carbon Steel -40 to 300°F (-40 to 149°C) B2 Ball Valve, Stainless Steel -40 to 300°F (-40 to 149°C) 4 (1) Annubar option selections may effect pressure and tem- perature limitations. Product Data Sheet 00813-0100-4028, Rev CA March 2008 Rosemount 285 Annubar Primary Element Installation Considerations Drill Hole Size According to Sensor Size Straight Run Requirements(1) (1) Consult the factory for instructions regarding use in Upstream Dimensions (Pipe Diameters) D o w n s tr e a m Without Vanes(2) With Vanes(3) In Plane A Out of Plane A A’ C C’ B 1 8 — 10 — — 8 — 4 — 4 4 4 2 11 — 16 — — 8 — 4 — 4 4 4 3 23 — 28 — — 8 — 4 — 4 4 4 4 12 — 12 — — 8 — 4 — 4 4 4 5 18 — 18 — — 8 — 4 — 4 4 4 6 30 — 30 — — 8 — 4 — 4 4 4 Flowmeter Orientation (Recommended) Gas (Horizontal) Liquid and Steam (Horizontal) Gas (Vertical) Steam (Vertical) Sensor Size Diameter 1 3/4-in. (19 mm) 2 15/16-in. (34 mm) 3030 120 30° 30° 120° F LO W 360° Note: Can also be mounted for Gas Vertical up applications. F LO W 360° In Plane Out of Plane 5 square or rectangular ducts. (2) “In Plane A” means the bar is in the same plane as the elbow. “Out of Plane A” means the bar is perpendicular to the plane of the upstream elbow. (3) Use straightening vane to reduce the required straight run length. Product Data Sheet 00813-0100-4028, Rev CA March 2008Rosemount 285 Annubar Primary Element Dimensional Drawings Pak-Lok Rosemount 285 Annubar Primary(1) (1) The Pak-Lok Annubar model is available up to 150# ANSI (275 psig at 100 °F (19 bar at 38 °C)). Front View Side View Top View A REMOTE MOUNT HEAD OPTION 1/4-in. NPT Connection B C TABLE 3. Rosemount 285 Annubar Primary - Pak-Lok Sensor Size A (Max) B (Max) C (Max) 1 8.50 (215.9) 5.00 (127.0) 9.00 (228.6) 2 11.00 (279.4) 5.00 (127.0) 9.00 (228.6) Dimensions are in inches (millimeters) 6 Product Data Sheet 00813-0100-4028, Rev CA March 2008 Rosemount 285 Annubar Primary Element Dimensional Drawings (continued) TABLE 4. Rosemount 285 Annubar with Duct Mount Duct Mount 285 Annubar Primary Front View Side View Top View Sensor Size A (Max) 1 7.00 (177.8) 2 9.00 (228.6) Dimensions are in inches (millimeters) A DIRECT MOUNT HEAD OPTION WITH VALVES (F2 OPTION) 7 Product Data Sheet 00813-0100-4028, Rev CA March 2008Rosemount 285 Annubar Primary Element Dimensional Drawings (continued) TABLE 5. Duct Mount with Compression Fitting Duct Mount with Compression Fitting 285 Annubar Primary Front View Side View Top View A DIRECT MOUNT HEAD OPTION WITH VALVES (F2 OPTION) Note Maximum opposite side stud length is 11/2-in. (38 mm) long. Sensor Size A (Max) 1 8.50 (215.9) 2 11.00 (279.4) Dimensions are in inches (millimeters) 8 Product Data Sheet 00813-0100-4028, Rev CA March 2008 Rosemount 285 Annubar Primary Element ORDERING INFORMATION Rosemount 285 Annubar Primary Ordering Information Model Annubar Primary Element 285 Economy Annubar Code Fluid Type L Liquid G Gas S Steam Code Line Size 020 2-in. (50 mm) 025 21/2-in. (63.5 mm) 030 3-in. (80 mm) 035 31/2-in. (89 mm) 040 4-in. (100 mm) 050 5-in. (125 mm) 060 6-in. (150 mm) 080 8-in. (200 mm) 100 10-in. (250 mm) 120 12-in. (300 mm) 140 14-in. (350 mm) 160 16-in. (400 mm) 180 18-in. (450 mm) 200 20-in. (500 mm) 240 24-in. (600 mm) 300 30-in. (750 mm) 360 36-in. (900 mm) 420 42-in. (1066 mm) 480 48-in. (1210 mm) 600 60-in. (1520 mm) 720 72-in. (1820 mm) 780 78-in. (1950 mm) 840 84-in. (2100 mm) 900 90-in. (2250 mm) 960 96-in. (2400 mm) Code Pipe I.D. Range (Refer to Pipe ID Range Table for Code) A Range A from the Pipe I.D. table B Range B from the Pipe I.D. table C Range C from the Pipe I.D. table D Range D from the Pipe I.D. table E Range E from the Pipe I.D. table Z Non-standard Pipe I.D. Range or Line Sizes greater than 12 inches (sensor size 2) or greater than 8 inches (sensor size 1). Code Piping Configuration C Circular R Rectangular or Square Code Pipe Material/Mounting Assembly Material C Carbon Steel S 316 Stainless Steel 0 No Mounting (Customer Supplied) Code Annubar Type P1 Pak-Lok 9 D1 Duct Mount Plate without Compression Fitting D2 Duct Mount Plate with Compression Fitting Continued on Next Page Product Data Sheet 00813-0100-4028, Rev CA March 2008Rosemount 285 Annubar Primary Element Code Sensor Material S 316 Stainless Steel Code Sensor Size 1 Sensor Size 1 2 Sensor Size 2 Code Electronics Connection Platform 3 Direct-mount 7 Remote-mount NPT Connections Code Options Instrument Connections for Remote Mount Option G1 Needle Valves, CS G2 Needle Valves, SS B1 Ball Valves, CS B2 Ball Valves, SS Variable Mount Height VM Variable Mounting Height for Customer Supplied Mounting Attach To H1 Attach to Transmitter Manifold F2(1) 3-Valve Manifold, SST Special Inspection(2) QC1 Visual and Dimensional Inspection w/Cert QC7 Inspection and Performance Certificate Material Traceability Certification (1) Q8 Material Cert per ISO 10474 3.1.B and EN 10204 3.1.B Special Shipment Y1 Mounting Hardware Shipped Separately (1) Applies to 285 Primary Element only. If F2 option is ordered with Electronic Connections Platform Code '3' (Direct Mount), manifold is integral to head. If F2 is ordered with Code '7' (Remote Mount), the manifold is supplied loose. (2) Applies to 285 Primary Element Only. 10 Product Data Sheet 00813-0100-4028, Rev CA March 2008 Rosemount 285 Annubar Primary Element Pipe I.D. Range Code–measured in inches (millimeters) See “Rosemount 285 Annubar Primary Ordering Information” on page 9 For pipes with an Inner Diameter (I.D.) Range / Pipe Wall Thickness not found in this table or with a line size greater than 12-in. (300 mm), choose option code Z and specify the exact pipe dimensions (I.D. and Pipe Wall Thickness) on the “” on page 11. The Emerson process Management sizing program will determine this code, based on the application piping. Line Size Inner Diameter (I.D.) Range Pipe Wall Thickness I.D. Range CodeNominal Max. O.D. Option Code ANSI Pipes Non-ANSI Pipes S e n s o r S iz e 1 2-in. (50 mm) 2.625-in. (66.68 mm) 020 1.784 to 1.841-in. (45.31 to 46.76 mm) 0.065 to 0.545-in. (1.7 to 13.8 mm) 0.065 to 0.488-in. (1.7 to 12.4 mm) A 1.842 to 1.938-in. (46.79 to 49.23 mm) 0.065 to 0.449-in. (1.7 to 11.4 mm) B 1.939 to 2.067-in. (49.25 to 52.50 mm) 0.065 to 0.417-in. (1.7 to 10.6 mm) C 2.068 to 2.206-in. (52.53 to 56.03 mm) 0.065 to 0.407-in. (1.7 to 10.3 mm) D 21/2-in. (63.5 mm) 3.188-in. (80.98 mm) 025 2.207 to 2.322-in. (56.06 to 58.98 mm) 0.083 to 0.563-in. (2.1 to 14.3 mm) 0.083 to 0.448-in. (2.1 to 11.4 mm) B 2.323 to 2.469-in. (59.00 to 62.71 mm) 0.083 to 0.417-in. (2.1 to 10.6 mm) C 2.470 to 2.598-in. (62.74 to 65.99 mm) 0.083 to 0.435-in. (2.1 to 11.0 mm) D 2.599 to 2.647-in. (66.01 to 67.23 mm) 0.083 to 0.515-in. (2.1 to 13.1 mm) E 3-in. (80 mm) 3.75-in. (95.25 mm) 030 2.648 to 2.751-in. (67.26 to 69.88 mm) 0.083 to 0.563-in. (2.1 to 14.3 mm) 0.083 to 0.460-in. (2.1 to 11.7 mm) A 2.752 to 2.899-in. (69.90 to 73.63 mm) 0.083 to 0.416-in. (2.1 to 10.6 mm) B 2.900 to 3.068-in. (73.66 to 77.93 mm) 0.083 to 0.395-in. (2.1 to 10.0 mm) C 3.069 to 3.228-in. (77.95 to 81.99 mm) 0.083 to 0.404-in (2.1 to 10.3 mm) D 31/2-in. (89 mm) 4.25-in. (107.95 mm) 035 3.229 to 3.333-in. (82.02 to 84.66 mm) 0.120 to 0.600-in. (3.0 to 15.2 mm) 0.120 to 0.496-in. (3.0 to 12.6 mm) B 3.334 to 3.548-in. (84.68 to 90.12 mm) 0.120 to 0.386-in. (3.0 to 9.8 mm) C 3.549 to 3.734-in. (90.14 to 94.84 mm) 0.120 to 0.415-in. (3.0 to 10.5 mm) D 4-in. (100 mm) 5.032-in. (127.81 mm) 040 3.735 to 3.825-in. (94.87 to 97.16 mm) 0.120 to 0.600-in. (3.0 to 15.2 mm) 0.120 to 0.510-in. (3.0 to 13.0 mm) B 3.826 to 4.026-in. (97.18 to 102.26 mm) 0.120 to 0.400-in. (3.0 to 10.2 mm) C 4.027 to 4.237-in. (102.29 to 107.62 mm) 0.120 to 0.390-in. (3.0 to 9.9 mm) D 4.238 to 4.437-in. (107.65 to 112.70 mm) 0.120 to 0.401-in. (3.0 to 10.2 mm) E 5-in. (125 mm) 6.094-in. (154.79 mm) 050 4.438 to 4.571-in. (112.73 to 116.10 mm) 0.134 to 0.614-in. (3.4 to 15.6 mm) 0.134 to 0.481-in. (3.4 to 12.2 mm) A 4.572 to 4.812-in. (116.13 to 122.22 mm) 0.134 to 0.374-in. (3.4 to 9.5 mm) B 4.813 to 5.047-in. (122.25 to 128.19 mm) 0.134 to 0.380-in. (3.4 to 9.7 mm) C 5.048 to 5.249-in. (128.22 to 133.32 mm) 0.134 to 0.413-in. (3.4 to 10.5 mm) D 6-in. (150 mm) 6.93-in. (176.02 mm) 060 5.250 to 5.472-in. (133.35 to 138.99 mm) 0.134 to 0.614-in. (3.4 to 15.6 mm) 0.134 to 0.392-in. (3.4 to 9.9 mm) A 5.473 to 5.760-in. (139.01 to 146.30 mm) 0.134 to 0.327-in. (3.4 to 8.3 mm) B 5.761 to 6.065-in. (146.33 to 154.05 mm) 0.134 to 0.310-in. (3.4 to 7.9 mm) C 6.066 to 6.383-in. (154.08 to 162.13 mm) 0.134 to 0.297-in. (3.4 to 7.5 mm) D 8-in. (200 mm) 9.688-in. (246.08 mm) 080 7.393 to 7.624-in. (187.78 to 193.65 mm) 0.250 to 0.73-in. (6.4 to 18.5 mm) 0.250 to 0.499-in. (6.4 to 12.6 mm) B 7.625 to 7.981-in. (193.68 to 202.72 mm) 0.250 to 0.374-in. (6.4 to 9.5 mm) C 7.982 to 8.400-in. (202.74 to 213.36 mm) 0.250 to 0.312-in. (6.4 to 7.9 mm) D 8.401 to 8.766-in. (213.39 to 222.66 mm) 0.250 to 0.364-in. (6.4 to 9.2 mm) E S e n s o r S iz e 2 8-in. (200 mm) 9.688-in. (246.08 mm) 080 7.393 to 7.624-in. (187.78 to 193.65 mm) 0.250 to 1.47-in. (6.4 to 37.3 mm) 0.250 to 1.239-in. (6.4 to 31.4 mm) B 7.625 to 7.981-in. (193.68 to 202.72 mm) 0.250 to 1.114-in. (6.4 to 28.3 mm) C 7.982 to 8.400-in. (202.74 to 213.36 mm) 0.250 to 1.052-in. (6.4 to 26.7 mm) D 8.401 to 8.766-in. (213.39 to 222.66 mm) 0.250 to 1.104-in. (6.4 to 28.0 mm) E 10-in. (250 mm) 11.75-in. (298.45 mm) 100 8.767 to 9.172-in. (222.68 to 232.97 mm) 0.250 to 1.470-in. (6.4 to 37.3 mm) 0.250 to 1.065-in. (6.4 to 27.1 mm) A 9.173 to 9.561-in. (232.99 to 242.85 mm) 0.250 to 1.082-in. (6.4 to 27.5 mm) B 9.562 to 10.020-in. (242.87 to 254.51 mm) 0.250 to 1.012-in. (6.4 to 25.7 mm) C 10.021 to 10.546-in. (254.53 to 267.87 mm) 0.250 to 0.945-in. (6.4 to 24.0 mm) D 10.547 to 10.999-in. (267.89 to 279.37 mm) 0.250 to 1.018-in. (6.4 to 25.9 mm) E 12-in. (300 mm) 13.0375-in. (331.15 mm) 120 11.000 to 11.373-in. (279.40 to 288.87 mm) 0.250 to 1.470-in. (6.4 to 37.3 mm) 0.250 to 1.097-in. (6.4 to 27.9 mm) B 11.374 to 11.938-in. (288.90 to 303.23 mm) 0.250 to 0.906-in. (6.4 to 23.0 mm) C 11.939 to 12.250-in. (303.25 to 311.15 mm) 0.250 to 1.159-in. (6.4 to 29.4 mm) D 11 Product Data Sheet 00813-0100-4028, Rev CA March 2008Rosemount 285 Annubar Primary Element Configuration Data Sheet (CDS) DP FLOW CDS Complete this form to define a custom flow configuration for DP Flowmeters. Unless specified, the flowmeter will be shipped with the default values identified by the H symbol. For technical assistance in filling out this CDS, call a Rosemount representative. NOTE Any missing information will be processed with the indicated default values. * = Required Item ★ = Default Customer Information Customer: Contact Name: Customer Phone: Customer Fax: Customer Approval Sign-Off: Customer PO: Calculation Approval ❑ Check this box if a calculation for approval prior to manufacturing is required Application and Configuration Data Sheet (Required with Order) Tag: Model No (1) * Select fluid type ❑ Liquid ❑ Gas ❑ Steam * Fluid name(2) Flowmeter Information (optional) * Failure Mode Alarm Direction (select one) ❑ Alarm High★ ❑ Alarm Low Software Tag: ___ ___ ___ ___ ___ ___ ___ ___ (8 characters) Descriptor: ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___ ___
/
本文档为【阿牛巴】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索