Related Topics Propagation of ultrasonic waves, time of flight, sound 超声波相关主题的传播,飞行时间,声音

2018-06-18 24页 doc 408KB 15阅读

用户头像

is_807289

暂无简介

举报
Related Topics Propagation of ultrasonic waves, time of flight, sound 超声波相关主题的传播,飞行时间,声音Related Topics Propagation of ultrasonic waves, time of flight, sound 超声波相关主题的传播,飞行时间,声音 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Related Topics Propagation of ultrasonic waves, time of flight, sound velocity,...
Related Topics Propagation of ultrasonic waves, time of flight, sound 超声波相关主题的传播,飞行时间,声音
Related Topics Propagation of ultrasonic waves, time of flight, sound 超声波相关主题的传播,飞行时间,声音 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Related Topics Propagation of ultrasonic waves, time of flight, sound velocity, damping of ultrasonic waves (scattering, reflection, absorption), transmission coefficient. Principle The damping of ultrasound in solid objects is determined for 2 (or optionally 3) different frequencies in the transmission mode. The resulting values are then compared to the corresponding literature values. In addition, the frequency dependence of the damping effect is analysed. Furthermore, the sound velocity in acrylic objects is determined for 2 (or optionally 3) different frequencies in the transmission mode. Equipment 1 Basic Set Ultrasonic echoscope 13921-99 consisting of: 1x Ultrasonic echoscope 1x Ultrasonic probe 1 MHz 1x Ultrasonic probe 2 MHz 1x Ultrasonic test block 1x Ultrasonic cylinder set 1x Ultrasonic test plates 1x Ultrasonic gel 1 Extension set: Shear waves 13921-03 consisting of: 1x Ultrasonic probe 1 MHz 1x Shear wave set (incl. 2 probe holders) 1x Aluminium sample for shear waves 1x Hydrophone for sound field measurement 1x Hydrophone plate 1x Hydrophone holder 1x Holder block 1 Ultrasonic Probe 2 MHz 13921-05 1 Vernier calliper 03010-00 Optionally 2 Ultrasonic Probe 4 MHz 13921-02 Additionally needed PC with USB port, Windows XP or higher Fig. 1: Equipment for Attenuation and velocity of ultrasound in solid state materials (transmission), experimental set-up P5160800 PHYWE Systeme GmbH & Co. KG ? All rights reserved 1 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Caution! Pay attention to the special operation and safety instructions in the manual of ultrasonic echoscope. Tasks 1. Measure the lengths of the three cylinders with the calliper. 2. Determine the amplitudes and times of flight of the ultrasonic transmission pulses for the three cy- linders and the two (or three) ultrasonic probes. 3. Calculate the attenuation and sound velocity values. Set-up and procedure - Set the experiment up as shown in Fig. 1. - The lengths of the cylinders must be measured with a vernier calliper. - In order to determine the time of flight and attenuation in the transmission mode, proceed as follows: Connect the echoscope to the PC. Insert the probes into the probe holders and connect the two probes (of the same frequency) to the “Probe connector (the switch must be set to “Trans.”). Insert the cylinder into the holder block. Start with the shortest one. Connect the probes to a cylinder with the aid of a drop of ultrasonic gel. - Damping measurement: Set the software to HF+Amp representation. The gain and transmission values must be set so that the signals for the shortest cylinders are not overdriven but are still as high as possible. If this is the case, the amplitude measurement is possible with all of the frequencies, including in connection with the longest cylinder (Figures 2, 3, 5, 7, 8, 10, 12, 13, and 15). It must be ensured that the gain settings are always identical in order to be able to compare the var- ious amplitude measurements. The measuring cursor for the amplitude determination is used to determine the amplitude of the transmission pulse at the three acrylic cylinders. If necessary, use the amplitude zoom function of the software in order to be able to analyse even small amplitudes with optimum precision (see Fig- ure 15). The maximum amplitude, comprising a negative and positive HF peak (red signal) and also based on the A-scan (blue signal), will be determined. This is repeated for all of the frequencies that are used. Note: Amplitude measurements should always be viewed critically, since the amplitude of the echo is not only influenced by the frequency-dependent damping effect and by the reflection coefficient of the material, but also by the coupling quality and alignment of the probes. In addition, the resolution of the digitalisation process (time and dynamic range) plays an important role. This is why the maxi- mum of the HF and amplitude signal should always be selected for damping measurements. - Sound velocity measurement: Set the gain, transmission power, and TGC so that the reception signal is slightly overdriven (Fig- ures 2, 4, 6, 7, 9, 11, 12, 14, and 16). The time of flight up to the beginning of the signal can be read off directly with the aid of the measuring cursors. This must be performed with great care, since time-of-flight measurement errors have a strong effect on the accuracy of the final results. If necessary, use the time zoom function of the software in order to optimally determine the point of onset (see Figure 16). Perform the measurement with all of the three cylinders and with probes of the same frequency. Note: The time-of-flight or depth measurements of an echo should be performed at the beginning of the rising edge of the peaks in the amplitude signal (if necessary, use the time zoom function). Time-of- flight measurements at the peak maximum can lead to incorrect results, since the peak shape can be influenced by the frequency-dependent damping effect. 2 PHYWE Systeme GmbH & Co. KG ? All rights reserved P5160800 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Software The “measure Ultra Echo” software records, displays, and evaluates the data that are transferred from the echoscope. After the start of the program, the measuring mode is active and the main screen “A- Scan mode” is displayed. All of the available actions and evaluations can be selected and started in this window. The upper part of the main screen shows the A-scan signal, the frequency of the connected transducer, and the operating mode (reflection/transmission). The current positions of the cursors (red and green line) are displayed at the bottom of the window. The cursors can be positioned by a mouse click. The time of flight is displayed under the cursor buttons. Note: Maintenance The ultrasonic cylinders and probes should be cleaned immediately after use with water or a standard detergent. Dried residues of ultrasonic gel are difficult to remove. If necessary, use a soft brush. Never use alcohol or liquids with solvents to clean the cylinders or probes. Deep surface scratches affect the coupling and can induce measurement errors. Fig. 2: 1 MHz probes, cylinder with approx. 40 mm, amplitude and time-of-flight measurement P5160800 PHYWE Systeme GmbH & Co. KG ? All rights reserved 3 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Fig. 3: 1 MHz probes, cylinder with approx. 80 mm, amplitude measurement Fig. 4: 1 MHz probes, cylinder with approx. 80 mm, time-of-flight measurement 4 PHYWE Systeme GmbH & Co. KG ? All rights reserved P5160800 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Fig. 5: 1 MHz probes, cylinder with approx. 120 mm, amplitude measurement Fig. 6: 1 MHz probes, cylinder with approx. 120 mm, time-of-flight measurement P5160800 PHYWE Systeme GmbH & Co. KG ? All rights reserved 5 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Fig. 7: 2 MHz probes, cylinder with approx. 40 mm, amplitude and time-of-flight measurement Fig. 8: 2 MHz probes, cylinder with approx. 80 mm, amplitude measurement 6 PHYWE Systeme GmbH & Co. KG ? All rights reserved P5160800 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Fig. 9: 2 MHz probes, cylinder with approx. 80 mm, time-of-flight measurement Fig. 10: 2 MHz probes, cylinder with approx. 120 mm, amplitude measurement P5160800 PHYWE Systeme GmbH & Co. KG ? All rights reserved 7 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Fig. 11: 2 MHz probes, cylinder with approx. 120 mm, time-of-flight measurement Fig. 12: 4 MHz probes, cylinder with approx. 40 mm, amplitude and time-of-flight measurement 8 PHYWE Systeme GmbH & Co. KG ? All rights reserved P5160800 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Fig. 13: 4 MHz probes, cylinder with approx. 80 mm, amplitude measurement Fig. 14: 4 MHz probes, cylinder with approx. 80 mm, time-of-flight measurement P5160800 PHYWE Systeme GmbH & Co. KG ? All rights reserved 9 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Fig. 15: 4 MHz probes, cylinder with approx. 120 mm, amplitude measurement with zoom ON Fig. 16: 4 MHz probes, cylinder with approx. 120 mm, time-of-flight measurement with zoom ON 10 PHYWE Systeme GmbH & Co. KG ? All rights reserved P5160800 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Theory and evaluation A sound wave that runs through a medium loses energy during various processes (scattering, absorption, and reflection). This is called attenuation. The intensity I of the wave follows the law of attenuation ,,s(1) I,Ie 0 where (I) is the initial intensity, (s) is the path length in the medium, and (µ) is the attenuation coefficient. O By measuring two samples of the same material but of different lengths, the material-specific attenuation coefficient (µ) can be determined by (2) that follows from (1) through a rearrangement. Here, it is taken into account that the intensity (I) is proportional to the square of the amplitude (A?) and that the conversion into the commonly used unit dB/cm results in [dB/cm][dB/cm],,(2) [1/cm]or[neper/cm],, ,20Lg(e)8.686 A2,8.6862 ,,Ln(s,s)A121 A short mechanical wave is generated by a short voltage pulse that is applied to a piezoelectric ceramic. If this wave is coupled into a solid object, it propagates in a linear way and it will be reflected and trans-mitted on areas with acoustic impedance changes (boundaries). From the known distance (s) of a material between two ultrasonic probes and the measured time of flight (t), the sound velocity (c) can be determined for perpendicular sound incidence as follows: sIn the transmission mode: (3) c,t The fact that nearly all of the ultrasonic probes have a protective layer on their active surface (ceramics) causes a measurement error concerning the sound velocity, since the time of flight through this layer is also measured. This means that the measured time of flight (t) includes the time of flight through the protective layers (tL1 and t2L) of the two probes and the time of flight through the sample (t). s This error can be eliminated if the velocity of sound (c) is determined by calculating the difference of two measurements (t and t) of two different sample lengths (s and s) and by assuming that the protective 1212 layers of the two probes are identical (t = t = t): L1L2L s,ss,ss,s,,,,,,121212c,,,(4) ,,,,t,tt,t,t,tt,t12S1LS2LS1S2 Results Measurement of the cylinder lengths with the vernier calliper (Table 1): P5160800 PHYWE Systeme GmbH & Co. KG ? All rights reserved 11 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 Length [mm] Cylinder 1 39.75 Cylinder 2 79.50 Cylinder 3 118.95 Amplitudes measured for three cylinders with different frequencies (Table 2): Amplitude [mV] 1 MHz 2 MHz 4 MHz Cylinder 1 920 984 1,000 Cylinder 2 450 394 179 Cylinder 3 219 147 29 Times of flight measured for three cylinders with different frequencies (Table 3): Time of flight [µs] 1 MHz 2 MHz 4 MHz Cylinder 1 15.1 14.9 14.8 Cylinder 2 29.7 29.5 29.4 Cylinder 3 44.2 44.0 43.9 Evaluation of the damping effect The measured amplitudes values (Table 2) for each of the frequencies can be used to calculate the damping values µ in 1/cm based on (2). 1 MHz probe: s1 A1 s2 A2 µ [mm] [mV] [mm] [mV] [1/cm] 39.75 920 79.50 450 3.13 79.50 450 118.95 219 3.17 39.75 920 118.95 219 3.15 Mean 3.15 2 MHz probe: s1 A1 s2 A2 µ [mm] [mV] [mm] [mV] [1/cm] 39.75 984 79.50 394 4.00 79.50 394 118.95 147 4.34 39.75 984 118.95 147 4.17 Mean 4.17 4 MHz probe: 12 PHYWE Systeme GmbH & Co. KG ? All rights reserved P5160800 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 s1 A1 s2 A2 µ [mm] [mV] [mm] [mV] [1/cm] 39.75 1000.0 79.50 179.0 7.52 79.50 179.0 118.95 29.0 8.01 39.75 1000.0 118.95 29.0 7.77 Mean 7.77 9Figure 17 shows the attenuation coefficient as a function of the ultrasound frequency. 8 The attenuation coefficient increases with an 7 increasing frequency. The resulting 6approximate dependence is described in (5): 5n(5) ,,fn,1.84 3Sound velocity evaluation attenuation coefficient2The measured values are used to calculate the sound velocity based on (3) (c1). In 1doing so, the time of flight through the adap- 0tation layers must be taken into considera- 1234tion, since it leads to an error concerning the calculated sound velocity. In order to elimi-frequency [MHz]nate this error, the sound velocity is deter-mined based on (4) by a difference calcula- tion of two measurements of the different Fig. 17: Attenuation coefficient vs. ultrasound frequency sample lengths (c2). 1 MHz probe: s1 t1 s2 t2 c1 c2 [mm] [µs] [mm] [µs] [m/s] [m/s] 39.75 15.1 79.50 29.7 2,632 2,723 79.50 29.7 118.95 44.2 2,677 2,721 118.95 44.2 39.75 15.1 2,691 2,722 Mean 2,667 2,722 2 MHz probe: s1 t1 s2 t2 c1 c2 [mm] [µs] [mm] [µs] [m/s] [m/s] 39.75 14.9 79.50 29.5 2,668 2,723 79.50 29.5 118.95 44.0 2,695 2,721 118.95 44.0 39.75 14.9 2,703 2,722 Mean 2,689 2,722 P5160800 PHYWE Systeme GmbH & Co. KG ? All rights reserved 13 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 1 MHz Probe2740 2720 2700 2680 2660c1 c22640Sound velocity [m/s] 262030,0080,00130,00 Thickness [mm] 2 MHz Probe2740 2720 2700 2680 2660c1 c22640 Sound velocity [m/s]262030,0080,00130,00 Thickness [mm] 4 MHz Probe2740 2720 2700 2680 2660c1 c22640 Sound velocity [m/s]262030,0080,00130,00 Thickness [mm] 14 PHYWE Systeme GmbH & Co. KG ? All rights reserved P5160800 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 4 MHz probe: s1 t1 s2 t2 c1 c2 [mm] [µs] [mm] [µs] [m/s] [m/s] 39.75 14.8 79.50 29.4 2,686 2,723 79.50 29.4 118.95 43.9 2,704 2,721 118.95 43.9 39.75 14.8 2,710 2,722 Mean 2,700 2,722 The thicker the adaptation layer is (and the smaller the frequency is), the greater the difference between c1 and c2 and, thereby, the error in the sound velocity determination. Literature value: longitudinal sound velocity in acrylic materials = 2,600-2,800 m/s. The measurement values concerning the sound velocity and attenuation coefficients in acrylic materials can vary strongly depending on the manufacturer and production method used. P5160800 PHYWE Systeme GmbH & Co. KG ? All rights reserved 15 TEAS Attenuation and velocity of ultrasound in solid 1.6.08 state materials (transmission) -00 16 PHYWE Systeme GmbH & Co. KG ? All rights reserved P5160800
/
本文档为【Related Topics Propagation of ultrasonic waves, time of flight, sound 超声波相关主题的传播,飞行时间,声音】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索