格力空调维修格力空调维修 空调错误 格力: 变频柜机E1-E5E1:压机过流,过热,排气过高,模块保护;E2:室内防冻结保 护; E3:室内温度感温包开,短路; E4:室内管温开,短路; E5:室内外通讯故障。: 定频机故障代码:E1:压缩机高压保护E2:蒸发器防冻结保护E3:压缩机低压保护E4: 压缩机排气温度过高保护E5:过电流(低电压保护) Gree: Frequency Guiji E1-E5E1: press overcurrent, overheating, excessive exhaust, module prot...
格力空调维修
格力空调维修 空调错误 格力: 变频柜机E1-E5E1:压机过流,过热,排气过高,模块保护;E2:室内防冻结保 护; E3:室内温度感温包开,短路; E4:室内管温开,短路; E5:室内外通讯故障。: 定频机故障代码:E1:压缩机高压保护E2:蒸发器防冻结保护E3:压缩机低压保护E4: 压缩机排气温度过高保护E5:过电流(低电压保护) Gree: Frequency Guiji E1-E5E1: press overcurrent, overheating, excessive exhaust, module protection; E2: indoor anti-freeze protection; E3: indoor temperature thermal package open, short circuit; E4: indoor pipe temperature open, short circuit ; E5: indoor and outdoor communication failure. : Fixed-frequency machine fault codes: E1: Compressor high pressure protection E2: Evaporator anti-freeze protection E3: compressor and low pressure protection E4: compressor discharge temperature protection E5: over-current (low voltage protection) E1是系统高压保护。故障原理:外机铜管连接的有个高压保护开关,通过高压开关检测系 统压力,然后通过线路反馈给芯片。维修流程:1.首先排除外界因素,如蒸发器,冷凝器脏, 电源缺相等。如果机器一开机就显示E1,看压缩机是否启动,若没启动测量高压开关,若 启动测压缩机启动电流。2.机器开一段时间显示E1,检查高压开关,和线路。可以短接高 压开关或OVC短接,排除某处的故障。 E1:为压缩机高压保护。 1、冷凝器前有障碍物 2、室外环境温度高于43度时开始制冷 、控制回路异常 4、高压管压力过大使高压开关动作 3 那么我们可以根据故障代码含义来分析,一般出现此故障的故障部位为:室外机散热不良、 清洗即可。室外风机不转或转的慢:决解,换风机、风扇电容器。高压保护故障:解决 方法,雪种过多,高压保护器损坏、信号线断或室内机控制板损坏。 E1 is a system-voltage protection. Fault Principle: brass connections outside the machine has a high voltage protection switch, through the high pressure switch detects the system pressure, then back to the chip via lines. Maintenance procedures: 1. First rule out external factors, such as evaporators, condensers dirty, lack of equal power. If the machine displays a boot on E1, to see if the compressor is started, if not start measuring high voltage switch, if the measured start the compressor starting current. 2. Machine open for some time to display E1, check the high voltage switch, and line. High-voltage switch can be shorted or OVC shorted somewhere exclude failures. E1: high-voltage protection for the compressor. 1, there is an obstacle before the condenser 2, when the outdoor temperature is higher than 43 degrees start cooling 3, the control circuit anomaly 4, the high-pressure pipe pressure Ambassador high voltage switching Then we can analyze the fault codes mean, generally faulty parts of this failure are: bad outdoor unit heat, can be cleaned. Slow outdoor fan does not turn or turn: decision solution method, for the fan, the fan capacitor. High pressure protection fault: Solution, refrigerant excessive, high-voltage protection is damaged, the signal line is broken or damaged indoor control board. E2:室内机蒸发器防冻结保护。 可能原因:故障代码E2:第一步先判断是控制故障还是系统故障,可先把室内管温包从蒸 发器中取出,如果不出现,则说明是系统问题;第二步检查室内环境温度是否太低,室内风 机转速是否太低,室内蒸发器是否太脏,系统是否堵塞。5. 开机显示故障代码E2:室内管 温器断路,造成误保护。6. 运行一段时间压缩机、室外风机停止,室内风机仍运转,显示 故障代码E2(灯箱型无显示):(1) 检查蒸发器是否结霜,若结霜,则显示故障代码E2。 其结霜原因可能是: 1) 系统缺氟,可用压力测系统压力、用钳表测运行电流,低压偏低 或电流偏小,则需加氟。 2) 气温偏低(25?以下)时,制冷运行蒸发器可能会结霜。 3) 蒸 发器表面脏,风量小。(2)如蒸发器未结霜,则可能是室内管温头位置不对,造成局部温 度过低,可将管温头移出再试。(3)室内管温感温包坏或折断。(4)也可能是显示器本身 故障或控制板问题。(5)过滤网太脏。(6)系统脏堵。(7)室内电动机转速太低。 E2: indoor evaporator anti-freeze protection. Possible causes: Error code E2: the first step is to determine fault or control system failure, the indoor pipe temperature can first be removed from the evaporator package, if you do not appear, the problem is the system; the second step is to check the ambient room temperature too low, the indoor fan speed is too low, the indoor evaporator is dirty, the system is blocked. 5. Power error code E2: indoor pipe temperature control circuit, causing malfunction protection. 6. Run a period of time of the compressor, outdoor fan stops, indoor fan is still running, error code E2 (light boxes without display) :( 1) Check whether the evaporator frost, if frost, the error code E2. Its frost reason may be: 1) lack of fluoride system, available gauge pressure measurement system, measured with a clamp operating current, low-voltage low or current is too small, you need fluoride. 2) low temperature (25 ? or less), the cooling operation may evaporator frost. 3) evaporator surface is dirty, the small amount of wind. (2) If the evaporator is not frosting, it may be the indoor pipe temperature head position is wrong, resulting in local temperature is too low, you can head out of the tube temperature and try again. (3) Indoor pipe temperature, temperature of bad or broken. (4) may also be a display fault or the board itself issues. (5) The filter is dirty. (6) The system fouling. (7) Indoor motor speed is too low. 制冷过负荷保护,即内机蒸发器结冰了,原因:1 老鼠把传感器线咬断可能性在百分之六 十以上,特别是饭店等公共场所。 2内机滤网脏堵,可能性一半以上。 3 内风机电容 量减小导致内风机转速低。4内机蒸发器后背太脏,导致蒸发器不通风。5传感器阻值漂移 Cooling overload protection, namely the machine evaporator freeze up because: 1 mouse sensor wires snapped the possibility of more than sixty percent, particularly in restaurants and other public places. 2 machine filter fouling, more than half of the possibility. 3 in the electrical and mechanical wind capacity is reduced resulting in lower internal fan speed. 4 machine evaporator back dirty, resulting in non-ventilated evaporator. 5 sensor resistance drift E3为压缩机吸气压力过低保护,建议检查:1.室内机循环风量过小,清洁室内机滤网。2. 系统制冷剂不足,添加制冷剂。 E3 for the compressor suction pressure is too low, we recommend that examination: 1. indoor circulating air volume is too small? Clean indoor unit filters. 2. Insufficient refrigerant system? Add refrigerant. E4保护:为排气管高温保护。压缩机起动后,连续30s检测到排气温度高于120?或排气 感温头短路(或开路)时,指示灯闪烁并显示故障代码E4。 E4 protection: an exhaust pipe temperature protection. After the compressor starts, continuous 30s detects a temperature higher than 120 ? exhaust or exhaust temperature sensor short circuit (or open), the light blinks and the fault code E4. 格力空调故障代码E5:低电压过流保护 可能出现的原因有以下: 1、电源电压低于187V,现在的空调都是宽电源,但是如果低于这个数字,空调也 是不能启动的~ 2、内机过滤网和外机的冷凝器太脏引起的保护,建议先清洗一下。 3、控制板故障,更换控制板 先检查一下电压是否正常,如果不稳定的话,建议安装稳压器,如果电压没有问题的 话,就联系厂家的专业人员上门吧~ Gree air-conditioning fault code E5: Low voltage over-current protection The following are possible reasons: 1, the supply voltage drops below 187V, the air conditioning is now wide power supply design, but if less than this figure, air conditioning is not activated! 2, the machine filters and outside the machine dirty condenser protection cause, it is recommended to wash. 3, the control board failure, replace the control board First check the voltage is normal, if unstable, it is recommended to install regulator, if the voltage is not a problem, just contact the manufacturers of professional home repair it! 一、格力空调三种机型显示E5的含意 1、格力定频空调显示E5代表——低电压保护(过电流保护)~ 2、格力变频空调显示e5代码——为室内外通讯故障 3、格力分体立柜式空调显示e5为——低电压保护,堵转过流保护 二、格力定频空调显示E5的维修方法 1、查看电压是否过低,可建议用户安装稳压器 2、外机电容是否损坏 3、外机散热是否良好,内机过滤网和外机的冷凝器是否太脏。 4、控制板故障,更换控制板 三、E5故障的系统诊断 1、压缩机运转后,连续3秒钟检测到电流超过6A 2、指示灯闪烁并显示E5。 First, Gree air-conditioning three models show the meaning E5 1, Gree fixed-frequency air show E5 Representative - Low-voltage protection (overcurrent protection)! 2, Gree inverter air conditioner displays e5 code - as indoor and outdoor communication failure 3, Gree air-conditioning closet split display e5 is - low voltage protection, overcurrent stall Second, Gree air-conditioning fixed-frequency display of maintenance methods E5 1. Check the voltage is too low, can recommend that users install the regulator 2, outside MOTORS damage 3, outside the machine cooling is good, the machine filters and the outdoor unit condenser is dirty. 4, control board failure, replace the control board Third, the system fault diagnosis E5 1, the operation of the compressor for 3 seconds detected current exceeds 6A 2, the light blinks and E5. 2.显示H6,是电机堵转或电机不转动故障。 3.E6代表你的内机太脏了。关掉主电源,打开下盖,抽出过滤网清 洗;用毛刷清洁那个静电除尘器。 格力空调故障代码E6的解决办法: 1.接线图外机电源盖上应该有的,如果按照图上所示接还是有问题 的话你你注意观察一下接线座上面的线,我遇到过别的品牌空调出厂时 座上面的线接错的,就是说假如2上面按图所示是N线但它接错了结果 上面连接到了信号线上,你按图接后就会出现不工作或工作不正常的现 象,好好看看想想。 2.死机:把电打下来几秒再打回去,开机试一下。 3.内外机信号线断或漏电,更换室内外连接信号电线再试机。 4.电路板坏,更换室内机电路主板。 格力空调显示E6的检修流程: 开关电源正常——5V电压正常吗——正常查通信光耦——外机接 线端——检修室内外信号线——N以通信线有跳变电压吗——没有查内 机——有查外机——晶振也查一下——更换电路主板。 3.2. Display H6, a motor stall fault or motor does not rotate. 4.3.E6 represent your machine dirty. Turn off the main power supply, open under cover, out of the filter cleaning; use a brush to clean the electrostatic precipitator. 5. 6.Gree air-conditioning fault code E6 solution: 7.1. The wiring diagram should cover some of the power out of the machine, if connected as shown in the figure is still a problem, then you look at your attention to terminal blocks above the line, I met other brands of air conditioning factory seat upper line access wrong, that if shown in Figure 2 above, but it is wrong N line connecting the above results to the signal line, and you will appear in Figure phenomenon is not working or not working properly followed, think a good look . 8.2. crashes: the power play call back down for a few seconds, turn try. 9.3. inside and outside the signal line is broken or leakage, replace the indoor and outdoor connecting signal wires try machine. 10.The circuit board is broken, replace the interior mechanical and electrical circuit board. 11. 12.Gree air-conditioning maintenance display E6 process: 13.Switching power supply voltage normal --5V normally do - Normal check communication optocouplers - terminal outside the machine - indoor and outdoor signal line --N overhaul to the communication line to the jump voltage do - did not check inside the machine - there are check outside the machine - Crystal also check - replace the circuit board. 14.E7模式冲突 在多联机上 常见 可能不同的内机开的模式不一样 有 的是制冷 有的是制热建议看下说明 15.E7 common mode of conflict on several different online may open the machine model is not the same as some heating and cooling some recommendations facie manual 16.E8控制面板和主控板之间通讯故障 查查是不是线被老鼠咬了~或者 插线排接触不良~ E8 between the control panel and the control board communication line failure look is not bitten by rats! Or Plug row is bad! 17.格力空调故障代码e8的有效解决方法: 故障机型:KFR-71LW 故障现象:开机能制冷,10分钟左右室内外机均停止工作,室内机面板显示E8的错误代码。 故障分析:经珠海格力空调维修师傅上门对机器进行检修,格力空调维修师傅根据格力空调故障代码表得 知e8代码的含义是:压缩机排气温度传感器1故障。顺着这个方向查下去很快便查到了故障所在位置。 首先检查压缩机排气温度传感器阻值是否正常,经检查没问题。再检查雪种压力是否过高,经证明雪种也 正常。开机观察室外出风量也够大,开机数分钟后发现室外机散出来的风越来越热,此时看到冷凝器翅片 上布满了灰尘,说明此机没有清洗保养过,故障原因就在这里。 解决方法:用专用的空调翅片清洗剂加入水于3比1比率对翅片进行清洗后开机试机运行正常,不再出现 e8代码,故障排除了。 18.Gree air-conditioning fault code e8 effective solution: 19.Fault models: KFR-71LW 20.Symptom: boot can Refrigeration, about 10 minutes of indoor and outdoor machines are stopped, the indoor unit panel display error code E8. 21.Failure Analysis: The Zhuhai Gree air-conditioning maintenance master site for machine maintenance, Gree air-conditioning maintenance, Gree air-conditioning fault code based on the master table e8 meaning that the code is: 1 compressor discharge temperature sensor fault. Investigation continues along this direction soon found the location of the fault. First check the compressor discharge temperature sensor resistance is normal, the check is no problem. Then check the refrigerant pressure is too high, it proved refrigerants are normal. Power observe outdoor air volume is large enough, a few minutes after the discovery of the outdoor unit power comes out of the air heats up, this time to see the condenser fins were covered with dust, indicating that this machine is not cleaning and maintenance too, cause of the malfunction in here. 22.Workaround: use special Fin Cleaner water was added after 3 to 1 ratio of fins to clean boot test machine operating normally, no longer appears e8 code, the troubleshooting.
/
本文档为【格力空调维修】,请使用软件OFFICE或WPS软件打开。作品中的文字与图均可以修改和编辑, 图片更改请在作品中右键图片并更换,文字修改请直接点击文字进行修改,也可以新增和删除文档中的内容。
[版权声明] 本站所有资料为用户分享产生,若发现您的权利被侵害,请联系客服邮件isharekefu@iask.cn,我们尽快处理。 本作品所展示的图片、画像、字体、音乐的版权可能需版权方额外授权,请谨慎使用。 网站提供的党政主题相关内容(国旗、国徽、党徽..)目的在于配合国家政策宣传,仅限个人学习分享使用,禁止用于任何广告和商用目的。

历史搜索

    清空历史搜索